LEESON Electric
2100 Washington Street • Grafton, WI 53024-0241 U.S.A.
TEL: (262) 377-8810 • FAX: (262) 377-9025
Printed in the U.S.A. - August 2002 • Document #: 250-0357, Revision 0
Copyright 2002 by LEESON Electric - All rights reserved. No part of this document may be reproduced or transmitted in any form without written permission from LEESON.
The information and technical data in this document are subject to change without notice. LEESON and its Divisions make no warranty of any kind with respect to this material,
including, but not limited to, the implied warranties of its merchantability and fitness for a given purpose. LEESON and its Divisions assume no responsibility for any errors
that may appear in this document and make no commitment to update or to keep current the information in this document.
174102 & 174107 NEMA4X SCR MOTOR CONTROLS
AC Line Voltage . . .115 VAC or 230 VAC, ±10%, 50/60 Hz, single phase
Horsepower Range with 115 VAC applied . . . . . . . . . . . . . . . .1/8 - 1 HP
Horsepower Range with 230 VAC applied . . . . . . . . . . . . . . . .1/4 - 2 HP
Maximum Armature Current . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 ADC
Maximum Field Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 ADC
Field Voltage
for 115 VAC Input . . . . . . .50 VDC (F1 to L1); 100 VDC (F1 to F2)
for 230 VAC Input . . . . . .100 VDC (F1 to L1); 200 VDC (F1 to F2)
Form Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.37 at base speed
Analog Input Voltage Range (signal must be isolated; S1 to S2):
for 0 - 90 VDC Armature Voltage . . . . . . . . . . . . . . . .0 - 1.4 VDC
for 0 - 180 VDC Armature Voltage . . . . . . . . . . . . . . .0 - 2.8 VDC
Input Impedance (S1 to S2) . . . . . . . . . . . . . . . . . . . . . . . . . . .3M ohms
Load Regulation . . . . . . . . . . . . . . . . . . . . . . . .1% base speed or better
Style . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NEMA 4X
174102 Non-Reversing Speed Control
1. Set the speed adjust dial to “0” (full CCW).
2. Apply AC line voltage.
3. Set the POWER switch to the ON position.
4. Slowly advance the speed adjust potentiometer CW.
The motor slowly accelerates as the potentiometer is
turned CW. Continue until the desired speed is reached.
5. To coast the motor to a stop, turn the speed adjust
potentiometer to “0” or set the POWER switch to the
OFF position.
174107 Reversing Speed Control
1. Set the FORWARD/OFF/REVERSE switch to the OFF
position.
2. Set the speed adjust potentiometer to “0” (full CCW).
3. Apply AC line voltage.
4. Set the FOWARD/OFF/REVERSE switch to the desired
direction of rotation.
5. Slowly advance the speed adjust potentiometer CW.
The motor slowly accelerates as the potentiometer is
turned CW. Continue until the desired speed is reached.
6. To coast the motor to a stop, turn the speed adjust
potentiometer to “0” or set the
FORWARD/OFF/REVERSE switch to the OFF position.
SPECIFICATIONS
OPERATION
CONNECTIONS
7. To reverse direction:
a. Set the FORWARD/OFF/REVERSE switch to the OFF
position.
b. After the motor comes to a complete stop, set the
FORWARD/OFF/REVERSE switch to the desired direction of
rotation.
QUICK START GUIDE