7.1 INPUT VOLTAGE RATINGS
Drives are rated for 120/208/240 Vac, single phase, 50-60 Hz input. The drive will function with input
voltage of 120 Vac (+10%, -15%), at 48 to 60 Hz, or with input voltage of 208 to 240 Vac (+10%,
-15%), at 48 to 62 Hz.
Drives that are rated for 208/240 Vac, three phase, 50-60 Hz input will function with input voltages of
208 to 240 Vac (+10%, -15%), at 48 to 62 Hz.
Drives that are rated for 208/240 Vac, single or three phase, 50-60 Hz input will function with input
voltage of 208 to 240 Vac (+10%, -15%), at 48 to 62 Hz.
Drives that are rated for 400/480 Vac, three phase, 50-60 Hz input will function with input voltages of
400 to 480 Vac (+10%, -15%), at 48 to 62 Hz.
Drives that are rated for 480/590 Vac, three phase, 50-60 Hz input will function with input voltages of
480 to 590 Vac (+10%, -15%), at 48 to 62 Hz.
NOTE: Parameter 01 - LINE VOLTAGE SELECTION must be programmed according to the applied
input voltage. See Section 15.0 - DESCRIPTION OF PARAMETERS.